The Valita L 220V series is a 10-120 kVA tower UPS with 3P/3P online double conversion, backfeed protection and true sine wave output, built on transformer-based (low frequency) technology with an isolation transformer. It is designed for 220V three-phase input and 220V three-phase output, for applications such as government, finance, IT, education, transportation, broadcasting, medical and energy.
Features
- Tower UPS with isolation transformer, transformer-based technology
- 220V three-phase input and 220V three-phase output
- Touch LCD with IoT functions
- IGBT rectifier and inverter
- Generator compatible
- Front access makes maintenance and replacement easy
- Online double conversion with backfeed protection, true sine wave output
10-120 kVAPower Range
1Output Power Factor
>0.99Input Power Factor
Valita L 220V Series Technical Specifications
10-40 kVA
| Model | Valita 22010 | Valita 22015 | Valita 22020 | Valita 22030 | Valita 22040 |
|---|---|---|---|---|---|
| Rated Power | 10kVA | 15kVA | 20kVA | 30kVA | 40kVA |
| MAIN INPUT | |||||
| Input | 3P5W (3P+N+PE) | ||||
| Rated Voltage | 200/208/220VAC (L-L) | ||||
| Rated Frequency | 50/60Hz | ||||
| Input PF | >0.99 | ||||
| Current Distortion | THDi <2% (100% linear load) | ||||
| Voltage Range | 146-270VAC (166-250VAC full load) | ||||
| Frequency Range | 50/60Hz ±5% | ||||
| BATTERY | |||||
| Rated Voltage | 360VDC (default 30 pcs, 28-32 pcs selectable) | ||||
| Charging Current | 1.8A (default), settable according to the battery settings | ||||
| INVERTER | |||||
| Rated Voltage | 200/208/220VAC (L-L) | ||||
| Rated Frequency | 50/60Hz | ||||
| Output PF | 1 | ||||
| Voltage Accuracy | ±1.0% | ||||
| Output THDu | <1% (linear load), <5% (non-linear load) | ||||
| Overload | 105% long time running 105-110% transfer to bypass in 1h 110-125% transfer to bypass in 10 mins 125-150% transfer to bypass in 1 min 150-200% transfer to bypass in 100 ms >200% transfer to bypass in 100 ms | ||||
| Frequency Accuracy | 0.1% | ||||
| Crest Factor | 3:1 | ||||
| SYSTEM | |||||
| Efficiency | up to 90% (95% in ECO mode) | ||||
| Display | LED + 7 inch touch LCD | ||||
| Safety Certification | IEC62040-1, IEC60950-1 | ||||
| EMS Certification | IEC62040-2; IEC61000-4-2 (ESD); IEC61000-4-3 (RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | ||||
| IP Degree | IP20 | ||||
| Configuration | RS232, RS485, dry contact | ||||
| Options | SNMP card, AS400 card, parallel kit | ||||
| Environment | 0-40°C (operation); -25°C ~ 70°C (storage); 0-95% (humidity, non-condensing) | ||||
| PHYSICAL | |||||
| Dimension W×D×H (mm) | 500*800*1600 | ||||
| Weight (kg) | 297 | 297 | 325 | 372 | 402 |
50-120 kVA
| Model | Valita 22050 | Valita 22060 | Valita 22080 | Valita 220100 | Valita 220120 |
|---|---|---|---|---|---|
| Rated Power | 50kVA | 60kVA | 80kVA | 100kVA | 120kVA |
| MAIN INPUT | |||||
| Input | 3P5W (3P+N+PE) | ||||
| Rated Voltage | 200/208/220VAC (L-L) | ||||
| Rated Frequency | 50/60Hz | ||||
| Input PF | >0.99 | ||||
| Current Distortion | THDi <2% (100% linear load) | ||||
| Voltage Range | 146-270VAC (166-250VAC full load) | ||||
| Frequency Range | 50/60Hz ±5% | ||||
| BATTERY | |||||
| Rated Voltage | 360VDC (default 30 pcs, 28-32 pcs selectable) | ||||
| Charging Current | 100A | 150A | 150A | 200A | 200A |
| INVERTER | |||||
| Rated Voltage | 200/208/220VAC (L-L) | ||||
| Rated Frequency | 50/60Hz | ||||
| Output PF | 1 | ||||
| Voltage Accuracy | ±1.0% | ||||
| Output THDu | <2% (linear load), <8% (non-linear load) | ||||
| Overload | 105% long time running 105-110% transfer to bypass in 1h 110-125% transfer to bypass in 10 mins 125-150% transfer to bypass in 1 min 150-200% transfer to bypass in 100 ms >200% transfer to bypass in 100 ms | ||||
| Frequency Accuracy | 0.1% | ||||
| Crest Factor | 3:1 | ||||
| SYSTEM | |||||
| Efficiency | up to 90% (95% in ECO mode) | ||||
| Display | LED + 7 inch touch LCD | ||||
| Safety Certification | IEC62040-1, IEC60950-1 | ||||
| EMS Certification | IEC62040-2; IEC61000-4-2 (ESD); IEC61000-4-3 (RS); IEC61000-4-4 (EFT); IEC61000-4-5 (Surge) | ||||
| IP Degree | IP20 | ||||
| Configuration | RS232, RS485, dry contact | ||||
| Options | SNMP card, AS400 card, parallel kit | ||||
| Environment | 0-40°C (operation); -25°C ~ 70°C (storage); 0-95% (humidity, non-condensing) | ||||
| PHYSICAL | |||||
| Dimension W×D×H (mm) | 600*800*1600 | 800*900*1800 | |||
| Weight (kg) | 460 | 590 | 630 | 690 | |
Specifications from the official Valita catalogue (Valita-L-220V-Low-Frequency-10-120kVA-2026.pdf). Specifications are subject to change without prior notice.